{"id":1618,"date":"2018-10-28T23:36:57","date_gmt":"2019-02-01T18:30:19","guid":{"rendered":"https:\/\/relequick.com\/?post_type=product&#038;p=1618"},"modified":"2019-02-02T09:32:48","modified_gmt":"2019-02-02T09:32:48","slug":"mcuxxxr2-current-monitoring-relay","status":"publish","type":"product","link":"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/","title":{"rendered":"MCUXXXR2 Current monitoring relay"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>[wp-svg-icons icon=\"paste-2\" wrap=\"i\" color=\"<span data-obj=\"color\">rgb(211, 19, 25, 1)<\/span>\"] <a href=\"https:\/\/relequick.com\/en\/#contacto\">OTHER DETAILS AND PRICE<\/a> <span style=\"color: #b11017;\">FEATURES<\/span><\/p>\n<hr \/>\n<ul>\n<li>Relequick&#8217;s current monitoring relay, especially designed for current monitoring on AC circuits and DC circuits.<\/li>\n<li>Up to 14 different functions: overcurrent, undercurrent, window&#8230; programming via software mode or 1-function overcurrent with trimmers (Manual mode).<\/li>\n<li>It provides protection of mechanical devices from jam-up or other overloading conditions that result in measurable increase in motor current.<\/li>\n<li>It compares the set intensity value to the real intensity supported by the circuit, activating the alarms and outputs of the relevant relays in order to protect the system against over and undercurrent between 0.5 to 10 A (250 V).<\/li>\n<li>MCUs must have a\u00a0external current transformer\u00a0attached if current is 10A or above\u00a0for accurate monitoring.<\/li>\n<li>Direct mounting on 35 mm rail.<\/li>\n<\/ul>\n<p><span style=\"color: #b11017;\">ATTACHED DOCUMENTS<\/span><\/p>\n<hr \/>\n<p>[wp-svg-icons icon=\"file-pdf\" wrap=\"i\" size=\"2em\" color=\"<span data-obj=\"color\">rgb(211, 19, 25, 1)<\/span>\"] Download installation guide: [download id=\"718\"] [wp-svg-icons icon=\"file-pdf\" wrap=\"i\" size=\"2em\" color=\"<span data-obj=\"color\">rgb(211, 19, 25, 1)<\/span>\"] Complete documentation: [download id=\"834\"] <span style=\"color: #b11017;\">Technical specifications<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td>Two time ranges<\/td>\n<td>0.1s &#8211; 30 s (Manual mode) 0.1s &#8211; 999h (Software mode)<\/td>\n<\/tr>\n<tr>\n<td>LED indicator<\/td>\n<td>PWR: indication of supply voltage (Green LED) ALM: current detection (Red LED)<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Terminal<\/div>\n<\/td>\n<td>\n<div>Niquel esta\u00f1ado<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Circuito de medici\u00f3n<\/div>\n<\/td>\n<td>\n<div>10 AAC<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Tiempo de detecci\u00f3n de corriente<\/div>\n<\/td>\n<td>\n<div>5 \u00b5s<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Max. current detection<\/div>\n<\/td>\n<td>\n<div>\u00a010 A (200 A with transformer)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Min. current detection<\/div>\n<\/td>\n<td>\n<div>0.5 A (20 A with transformador)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Phase detection<\/div>\n<\/td>\n<td>\n<div>1-phase<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #b11017;\">Input circuit<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td>\n<div>Power supply<\/div>\n<\/td>\n<td>\n<div>12 &#8211; 24 VAC\/VDC<\/div>\n<div>110 &#8211; 230 VAC\/VDC<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Operating frequency (AC)<\/div>\n<\/td>\n<td>\n<div>\u00a050\/60Hz<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #b11017;\">Output circuit<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td>Contact configuration<\/td>\n<td>\n<div>2xSPST( rel\u00e9 1 NO, rel\u00e9 2 NC)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Max. switching voltage<\/div>\n<\/td>\n<td>\n<div>250 VAC1 \/ 30 VDC1<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Max. peak current<\/td>\n<td>6A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #b11017;\">Current setting<\/span><\/p>\n<hr \/>\n<div>The module can be used in two different ways:<\/div>\n<div><strong>Manual mode<\/strong>: configure the function 0 only using the trimmer.<\/div>\n<div><strong>Programming mode<\/strong>: with our \u201cDevices Programmer\u201d software* it is possible to program easily over\/under\/window current functions, from 0.5 to 10 A.<\/div>\n<div><\/div>\n<div>*Availabe for Windows XP, 7 and 8.<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":1361,"template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>MCUXXXR2 Current monitoring relay - Rel\u00e9s y Bases<\/title>\n<meta name=\"description\" content=\"Relequick\u2019s current monitoring relay, especially designed for current monitoring on AC circuits and DC circuits\" \/>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/relequick.com\/shop\/mcuxxxr2-current-monitoring-relay\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MCUXXXR2 Current monitoring relay - Rel\u00e9s y Bases\" \/>\n<meta property=\"og:description\" content=\"Relequick\u2019s current monitoring relay, especially designed for current monitoring on AC circuits and DC circuits\" \/>\n<meta property=\"og:url\" content=\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/\" \/>\n<meta property=\"og:site_name\" content=\"Rel\u00e9s y Bases\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/es-es.facebook.com\/people\/Spainae-Spainae\/100014115632622\" \/>\n<meta property=\"article:modified_time\" content=\"2019-02-02T09:32:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/mcuxxxr2-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"875\" \/>\n\t<meta property=\"og:image:height\" content=\"506\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Relequick\" \/>\n<meta name=\"twitter:site\" content=\"@Relequick\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/relequick.com\/en\/#organization\",\"name\":\"Relequick\",\"url\":\"https:\/\/relequick.com\/en\/\",\"sameAs\":[\"https:\/\/es-es.facebook.com\/people\/Spainae-Spainae\/100014115632622\",\"https:\/\/www.linkedin.com\/company\/relequick-s-a-\",\"https:\/\/www.youtube.com\/channel\/UC0DOveNmm18Qy0UP5VA1ymQ\",\"https:\/\/www.pinterest.es\/sautomationequipment\/\",\"https:\/\/twitter.com\/Relequick\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/relequick.com\/en\/#logo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/logo-relequick.png\",\"width\":200,\"height\":116,\"caption\":\"Relequick\"},\"image\":{\"@id\":\"https:\/\/relequick.com\/en\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/relequick.com\/en\/#website\",\"url\":\"https:\/\/relequick.com\/en\/\",\"name\":\"Rel\\u00e9s y Bases\",\"description\":\"Rel\\u00e9s de estado s\\u00f3lido y electromec\\u00e1nicos\",\"publisher\":{\"@id\":\"https:\/\/relequick.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/relequick.com\/en\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/mcuxxxr2-1.jpg\",\"width\":875,\"height\":506},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/#webpage\",\"url\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/\",\"name\":\"MCUXXXR2 Current monitoring relay - Rel\\u00e9s y Bases\",\"isPartOf\":{\"@id\":\"https:\/\/relequick.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/#primaryimage\"},\"datePublished\":\"2019-02-01T18:30:19+00:00\",\"dateModified\":\"2019-02-02T09:32:48+00:00\",\"description\":\"Relequick\\u2019s current monitoring relay, especially designed for current monitoring on AC circuits and DC circuits\",\"breadcrumb\":{\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/\",\"url\":\"https:\/\/relequick.com\/\",\"name\":\"Portada\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/\",\"url\":\"https:\/\/relequick.com\/en\/shop\/\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/\",\"url\":\"https:\/\/relequick.com\/en\/shop\/mcuxxxr2-current-monitoring-relay\/\",\"name\":\"MCUXXXR2 Current monitoring relay\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/1618\/"}],"collection":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/"}],"about":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/types\/product\/"}],"version-history":[{"count":0,"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/1618\/revisions\/"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/media\/1361\/"}],"wp:attachment":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/media\/?parent=1618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}