{"id":1739,"date":"2018-10-22T09:20:07","date_gmt":"2019-02-01T18:59:09","guid":{"rendered":"https:\/\/relequick.com\/?post_type=product&#038;p=1739"},"modified":"2019-02-03T12:04:55","modified_gmt":"2019-02-03T12:04:55","slug":"rpa-30-amps-power-relay","status":"publish","type":"product","link":"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/","title":{"rendered":"RPA 30 Amps, power relay"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>[wp-svg-icons icon=\"paste-2\" wrap=\"i\" color=\"<span data-obj=\"color\">rgb(211, 19, 25, 1)<\/span>\"] <span style=\"color: #b11017;\"> <a href=\"https:\/\/relequick.com\/en\/#contacto\">OTHER DETAILS AND PRICE<\/a><\/span> <span style=\"color: #b11017;\">FEATURES<\/span><\/p>\n<hr \/>\n<ul>\n<li>\u00a0High power relay designed for high current load applications.<\/li>\n<li>Available in 1 &amp; 2 NO contacts with max. current 30 \/\u00a025A.<\/li>\n<li>Available with flanges for panel or DIN rail, and faston or screw terminals.<\/li>\n<li>Nominal power 1.9 W (DC) &amp; 2.5 VA (AC).<\/li>\n<li>Insulation:\u00a0IEC61810-1 &#8211; 2.5 KV\/3.<\/li>\n<li>Pollution degree: 2<\/li>\n<li>Protection class: IP20.<\/li>\n<li>Approvals: CE.<\/li>\n<li>European approvalS.<\/li>\n<\/ul>\n<p><span style=\"color: #b11017;\">ATTACHED DOCUMENTS<\/span><\/p>\n<hr \/>\n<p>[wp-svg-icons icon=\"file-pdf\" wrap=\"i\" size=\"2em\" color=\"<span data-obj=\"color\">rgb(211, 19, 25, 1)<\/span>\"] Download file: [download id=\"790\"] <span style=\"color: #b11017;\">COIL SPECIFICATION<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\" align=\"left\">\n<tbody>\n<tr>\n<td>Rated voltage\u00a0(VDC)<\/td>\n<td>\n<div>6<\/div>\n<\/td>\n<td>\n<div>12<\/div>\n<\/td>\n<td>\n<div>24<\/div>\n<\/td>\n<td>\n<div>48<\/div>\n<\/td>\n<td>\n<div>115<\/div>\n<\/td>\n<td>\n<div>&#8211;<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Potencia nominal\u00a0AC (VA) \/\u00a0DC (W)<\/td>\n<td colspan=\"6\" rowspan=\"1\">\n<div>2.5 \/ 1.9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage\u00a0(VAC)<\/td>\n<td>\n<div>6<\/div>\n<\/td>\n<td>\n<div>12<\/div>\n<\/td>\n<td>\n<div>24<\/div>\n<\/td>\n<td>\n<div>48<\/div>\n<\/td>\n<td>\n<div>120<\/div>\n<\/td>\n<td>\n<div>230<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #b11017;\">CONTACT SPECIFICATION<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\" align=\"left\">\n<tbody>\n<tr>\n<td>\n<div>Contact configuration<\/div>\n<\/td>\n<td>\n<div>1C &amp; 2C (NO)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Rated load<\/td>\n<td>\n<div>7.500 &amp; 6.250 VAC1<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Max. switching voltage<\/td>\n<td>\n<div>250 VAC<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Max. breaking capacity<\/div>\n<\/td>\n<td>\n<div>7.500 VA \/ 840W, \u00a0AC1 2.500 \/ DC1 30V<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Contact resistance<\/div>\n<\/td>\n<td>\n<div>\u226450 m\u03a9<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Contact material<\/div>\n<\/td>\n<td>\n<div>AgNi<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #b11017;\">GENERAL DATA<\/span><\/p>\n<hr \/>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\" align=\"left\">\n<tbody>\n<tr>\n<td>\n<div>Electrical life<\/div>\n<\/td>\n<td>\n<div>\u226510<sup>5<\/sup> cycles<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Mechanical life<\/div>\n<\/td>\n<td>\n<div>\u22655&#215;10<sup>5<\/sup>\u00a0cycles<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Operate\/release time<\/div>\n<\/td>\n<td>\n<div>\u2264 30 ms<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Ambient temperature range<\/div>\n<\/td>\n<td>\n<div>-40\u00baC &#8230; +65\u00baC<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Relative humidity<\/div>\n<\/td>\n<td>\n<div>35% &#8211; 85% RH<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Atmospheric pressure<\/div>\n<\/td>\n<td>\n<div>86 &#8211; 106 KPa<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div>Weight<\/div>\n<\/td>\n<td>\n<div>91 gr (terminales faston)<\/div>\n<div>123 gr (terminales tornillo)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Units per package<\/td>\n<td>\n<div>10<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":1750,"template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RPA 30 Amps, power relay - Rel\u00e9s y Bases<\/title>\n<meta name=\"description\" content=\"High power relay loads up 30 A with 1 or 2 open contacts. Flanges panel or rail DIN, insulation standard IEC61810-1 of 2,5 Kv \/ 3, pollution 2, CE Marking\" \/>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/relequick.com\/shop\/rpa-30-amps-power-relay\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RPA 30 Amps, power relay - Rel\u00e9s y Bases\" \/>\n<meta property=\"og:description\" content=\"High power relay loads up 30 A with 1 or 2 open contacts. Flanges panel or rail DIN, insulation standard IEC61810-1 of 2,5 Kv \/ 3, pollution 2, CE Marking\" \/>\n<meta property=\"og:url\" content=\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/\" \/>\n<meta property=\"og:site_name\" content=\"Rel\u00e9s y Bases\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/es-es.facebook.com\/people\/Spainae-Spainae\/100014115632622\" \/>\n<meta property=\"article:modified_time\" content=\"2019-02-03T12:04:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/relequick_rpa1an024acht.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3264\" \/>\n\t<meta property=\"og:image:height\" content=\"2448\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Relequick\" \/>\n<meta name=\"twitter:site\" content=\"@Relequick\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/relequick.com\/en\/#organization\",\"name\":\"Relequick\",\"url\":\"https:\/\/relequick.com\/en\/\",\"sameAs\":[\"https:\/\/es-es.facebook.com\/people\/Spainae-Spainae\/100014115632622\",\"https:\/\/www.linkedin.com\/company\/relequick-s-a-\",\"https:\/\/www.youtube.com\/channel\/UC0DOveNmm18Qy0UP5VA1ymQ\",\"https:\/\/www.pinterest.es\/sautomationequipment\/\",\"https:\/\/twitter.com\/Relequick\"],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/relequick.com\/en\/#logo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/logo-relequick.png\",\"width\":200,\"height\":116,\"caption\":\"Relequick\"},\"image\":{\"@id\":\"https:\/\/relequick.com\/en\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/relequick.com\/en\/#website\",\"url\":\"https:\/\/relequick.com\/en\/\",\"name\":\"Rel\\u00e9s y Bases\",\"description\":\"Rel\\u00e9s de estado s\\u00f3lido y electromec\\u00e1nicos\",\"publisher\":{\"@id\":\"https:\/\/relequick.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/relequick.com\/en\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/relequick.com\/wp-content\/uploads\/2018\/10\/relequick_rpa1an024acht.jpg\",\"width\":3264,\"height\":2448},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/#webpage\",\"url\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/\",\"name\":\"RPA 30 Amps, power relay - Rel\\u00e9s y Bases\",\"isPartOf\":{\"@id\":\"https:\/\/relequick.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/#primaryimage\"},\"datePublished\":\"2019-02-01T18:59:09+00:00\",\"dateModified\":\"2019-02-03T12:04:55+00:00\",\"description\":\"High power relay loads up 30 A with 1 or 2 open contacts. Flanges panel or rail DIN, insulation standard IEC61810-1 of 2,5 Kv \/ 3, pollution 2, CE Marking\",\"breadcrumb\":{\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/\",\"url\":\"https:\/\/relequick.com\/\",\"name\":\"Portada\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/\",\"url\":\"https:\/\/relequick.com\/en\/shop\/\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/\",\"url\":\"https:\/\/relequick.com\/en\/shop\/rpa-30-amps-power-relay\/\",\"name\":\"RPA 30 Amps, power relay\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/1739\/"}],"collection":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/"}],"about":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/types\/product\/"}],"version-history":[{"count":0,"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/product\/1739\/revisions\/"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/media\/1750\/"}],"wp:attachment":[{"href":"https:\/\/relequick.com\/en\/wp-json\/wp\/v2\/media\/?parent=1739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}